rm -Rf /opt/metwork-mfdata-1.2/mfdata-1.2.2-617 ; mkdir /opt/metwork-mfdata-1.2/mfdata-1.2.2-617 for REP in /opt/metwork-mfdata-1.2/*; do \ if test "" = "1"; then continue; fi; \ if ! test -d "${REP}"; then continue; fi; \ if test "${REP}" = "/opt/metwork-mfdata-1.2/build"; then continue; fi; \ if test "${REP}" = "/opt/metwork-mfdata-1.2/src"; then continue; fi; \ if [[ ${REP} = /opt/metwork-mfdata-1.2/mfdata-* ]]; then continue; fi; \ cp -Rpf ${REP} /opt/metwork-mfdata-1.2/mfdata-1.2.2-617/; \ done if test "" = "1"; then \ mkdir -p /opt/metwork-mfdata-1.2/mfdata-1.2.2-617/opt; \ for REP in /opt/metwork-mfdata-1.2/opt/*; do \ if ! test -d "${REP}"; then continue; fi; \ if ! test -f ${REP}/.mfextaddon; then continue; fi; \ if test "`cat ${REP}/.mfextaddon 2>/dev/null`" != ""; then continue; fi; \ cp -Rpf ${REP} /opt/metwork-mfdata-1.2/mfdata-1.2.2-617/opt/; \ done; \ else \ cp -f /opt/metwork-mfdata-1.2/.layerapi2* /opt/metwork-mfdata-1.2/mfdata-1.2.2-617/; \ cp -f /opt/metwork-mfdata-1.2/.dhash* /opt/metwork-mfdata-1.2/mfdata-1.2.2-617/ 2>/dev/null || true; \ fi chmod -R go-rwx /opt/metwork-mfdata-1.2/mfdata-1.2.2-617 chmod -R ug+rX /opt/metwork-mfdata-1.2/mfdata-1.2.2-617 chmod -R u+rwX /opt/metwork-mfdata-1.2/mfdata-1.2.2-617 rm -f /opt/metwork-mfdata-1.2/mfdata-1.2.2-617/mf*_link rm -f /opt/metwork-mfdata-1.2/mfdata-1.2.2-617/*.tar rm -f /opt/metwork-mfdata-1.2/mfdata-1.2.2-617/*.rpm rm -Rf /opt/metwork-mfdata-1.2/mfdata-1.2.2-617/tmp >/dev/null 2>&1 rm -Rf /opt/metwork-mfdata-1.2/mfdata-1.2.2-617/var >/dev/null 2>&1 rm -Rf /opt/metwork-mfdata-1.2/mfdata-1.2.2-617/log >/dev/null 2>&1 rm -Rf /opt/metwork-mfdata-1.2/mfdata-1.2.2-617/runtime >/dev/null 2>&1 cd /opt/metwork-mfdata-1.2 && tar -cf mfdata-1.2.2-617-linux64.tar mfdata-1.2.2-617 rm -Rf /opt/metwork-mfdata-1.2/mfdata-1.2.2-617 rm -Rf /opt/metwork-mfdata-1.2/rpm mkdir /opt/metwork-mfdata-1.2/rpm mkdir /opt/metwork-mfdata-1.2/rpm/BUILD mkdir /opt/metwork-mfdata-1.2/rpm/RPMS mkdir /opt/metwork-mfdata-1.2/rpm/SRPMS mkdir /opt/metwork-mfdata-1.2/rpm/SPECS mkdir /opt/metwork-mfdata-1.2/rpm/SOURCES mkdir /opt/metwork-mfdata-1.2/rpm/tmp echo '%_topdir /opt/metwork-mfdata-1.2/rpm' >/opt/metwork-mfdata-1.2/rpm/.rpmmacros cat /opt/metwork-mfext-1.2/share/_metwork.spec | /opt/metwork-mfext-1.2/bin/envtpl --reduce-multi-blank-lines >/opt/metwork-mfdata-1.2/rpm/SPECS/metwork-mfdata.spec echo /opt/metwork-mfdata-1.2/rpm/SPECS/metwork-mfdata.spec /opt/metwork-mfdata-1.2/rpm/SPECS/metwork-mfdata.spec ln -s /opt/metwork-mfdata-1.2/mfdata-1.2.2-617-linux64.tar /opt/metwork-mfdata-1.2/rpm/SOURCES/mfdata-1.2.2-617-linux64.tar cd /opt/metwork-mfdata-1.2/rpm/SPECS && export HOME=/opt/metwork-mfdata-1.2/rpm && rpmbuild -bb metwork-mfdata.spec Executing(%prep): /bin/sh -e /var/tmp/rpm-tmp.1VyKW1 + umask 022 + cd /opt/metwork-mfdata-1.2/rpm/BUILD + LANG=C + export LANG + unset DISPLAY + cd /opt/metwork-mfdata-1.2/rpm/BUILD + rm -Rf metwork-mfdata-1.2.2-617 + rm -Rf mfdata-1.2.2-617 + cat /opt/metwork-mfdata-1.2/rpm/SOURCES/mfdata-1.2.2-617-linux64.tar + tar -xf - + mkdir metwork-mfdata-1.2.2-617 + mv mfdata-1.2.2-617 metwork-mfdata-1.2.2-617/ + cd metwork-mfdata-1.2.2-617 + rm -f 'mf*_link' + exit 0 Executing(%build): /bin/sh -e /var/tmp/rpm-tmp.2qTTXo + umask 022 + cd /opt/metwork-mfdata-1.2/rpm/BUILD + LANG=C + export LANG + unset DISPLAY + exit 0 Executing(%install): /bin/sh -e /var/tmp/rpm-tmp.l1snZL + umask 022 + cd /opt/metwork-mfdata-1.2/rpm/BUILD + '[' /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64 '!=' / ']' + rm -rf /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64 ++ dirname /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64 + mkdir -p /opt/metwork-mfdata-1.2/rpm/BUILDROOT + mkdir /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64 + LANG=C + export LANG + unset DISPLAY + mkdir -p /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64//opt/metwork-mfdata-1.2 + ln -s /opt/metwork-mfdata-1.2 /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64/opt/metwork-mfdata + mkdir -p /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64/home/mfdata + mv metwork-mfdata-1.2.2-617/mfdata-1.2.2-617/bin metwork-mfdata-1.2.2-617/mfdata-1.2.2-617/config metwork-mfdata-1.2.2-617/mfdata-1.2.2-617/html_doc metwork-mfdata-1.2.2-617/mfdata-1.2.2-617/lib metwork-mfdata-1.2.2-617/mfdata-1.2.2-617/opt metwork-mfdata-1.2.2-617/mfdata-1.2.2-617/share /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64/opt/metwork-mfdata-1.2/ + mv metwork-mfdata-1.2.2-617/mfdata-1.2.2-617/.layerapi2_dependencies metwork-mfdata-1.2.2-617/mfdata-1.2.2-617/.layerapi2_label /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64/opt/metwork-mfdata-1.2/ + mv metwork-mfdata-1.2.2-617/mfdata-1.2.2-617/.dhash /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64/opt/metwork-mfdata-1.2/ + rm -Rf /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64/opt/metwork-mfdata-1.2/html_doc + ln -s /opt/metwork-mfdata-1.2/share/bashrc /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64/home/mfdata/.bashrc + ln -s /opt/metwork-mfdata-1.2/share/bash_profile /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64/home/mfdata/.bash_profile + chmod -R go-rwx /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64/home/mfdata + chmod -R u+rX /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64/home/mfdata + chmod g+rx /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64/home/mfdata + chmod -R a+rX /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64/opt/metwork-mfdata-1.2 + rm -Rf /opt/metwork-mfdata-1.2/rpm/BUILD/metwork-mfdata-1.2.2-617 + /usr/lib/rpm/check-buildroot Processing files: metwork-mfdata-1.2.2-617.gen.x86_64 Processing files: metwork-mfdata-1.2-1.2.2-617.gen.x86_64 Processing files: metwork-mfdata-full-1.2.2-617.gen.x86_64 Checking for unpackaged file(s): /usr/lib/rpm/check-files /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64 Wrote: /opt/metwork-mfdata-1.2/rpm/RPMS/x86_64/metwork-mfdata-1.2.2-617.gen.x86_64.rpm Wrote: /opt/metwork-mfdata-1.2/rpm/RPMS/x86_64/metwork-mfdata-1.2-1.2.2-617.gen.x86_64.rpm Wrote: /opt/metwork-mfdata-1.2/rpm/RPMS/x86_64/metwork-mfdata-full-1.2.2-617.gen.x86_64.rpm Executing(%clean): /bin/sh -e /var/tmp/rpm-tmp.7AoKah + umask 022 + cd /opt/metwork-mfdata-1.2/rpm/BUILD + rm -fr /opt/metwork-mfdata-1.2/rpm/BUILDROOT/metwork-mfdata-1.2.2-617.gen.x86_64 + exit 0 if test "" = "1"; then rm -f $(ls /opt/metwork-mfdata-1.2/rpm/RPMS/x86_64/*.rpm |grep -v '\-layer\-'); fi cp -f /opt/metwork-mfdata-1.2/rpm/RPMS/x86_64/*.rpm /opt/metwork-mfdata-1.2/ if test ! "true" = true; then rm -Rf /opt/metwork-mfdata-1.2/rpm; fi